Three phase reversible Autotransformer IP23

Three phase reversible autotransformer dry type without galvanic isolation, designed to change voltage 400V / 230V. Construction into enclosure, protection degree IP-23. Its main advantage is that can be used to increase as much as reduce voltage (reversible).

 
 
    
Power rating
3 ÷ 1.000 kVA
Input voltage
3 x 400 V + N
Output voltage
3 x 230 V
Connection group
YN0
Frequency50/60 Hz
Ambient temp.
30 ºC
Insulation class
F (155ºC) up to ATC0315
H (180ºC) from ATC0400
Protection degree
IP-23
Safety class
Class I
Test voltage
3 kV
MarkedCE
StandardIEC/UNE-EN 61558-1
IEC/UNE-EN 61558-2-13
IEC/UNE-EN 60076-11


 

Series ATC

613 KB

 
 
 

Electrical diagram

 

 

 

Dimensions

 

* TORYTRANS reserves the right to modify the information in any time
and without prior notice. Design, dimensions or weight of the product could be different. *

 
 
Versiones 1 to 1 of 1
 ATC003ATC004ATC006ATC008ATC010ATC012ATC016ATC020ATC025ATC031ATC040ATC050ATC063ATC080ATC100ATC125ATC160ATC200ATC250ATC315ATC400ATC500ATC630ATC800ATC1000
Request offerRequestRequestRequestRequestRequestRequestRequestRequestRequestRequestRequestRequestRequestRequestRequestRequestRequestRequestRequestRequestRequestRequestRequestRequestRequest
Power (VA)3000400060008000100001200016000200002500031500400005000063000800001000001250001600002000002500003150004000005000006300008000001000000
PRI (V)400400400400400400400400400400400400400400400400400400400400400400400400400
SEC (V)230230230230230230230230230230230230230230230230230230230230230230230230230
IP23232323232323232323232323232323232323232323232323
PhasesThree-phaseThree-phaseThree-phaseThree-phaseThree-phaseThree-phaseThree-phaseThree-phaseThree-phaseThree-phaseThree-phaseThree-phaseThree-phaseThree-phaseThree-phaseThree-phaseThree-phaseThree-phaseThree-phaseThree-phaseThree-phaseThree-phaseThree-phaseThree-phaseThree-phase
UseReversibleReversibleReversibleReversibleReversibleReversibleReversibleReversibleReversibleReversibleReversibleReversibleReversibleReversibleReversibleReversibleReversibleReversibleReversibleReversibleReversibleReversibleReversibleReversibleReversible
Frequency50/60 Hz50/60 Hz50/60 Hz50/60 Hz50/60 Hz50/60 Hz50/60 Hz50/60 Hz50/60 Hz50/60 Hz50/60 Hz50/60 Hz50/60 Hz50/60 Hz50/60 Hz50/60 Hz50/60 Hz50/60 Hz50/60 Hz50/60 Hz50/60 Hz50/60 Hz50/60 Hz50/60 Hz50/60 Hz
Ambient temperature40ºC40ºC40ºC40ºC40ºC40ºC40ºC40ºC40ºC40ºC40ºC40ºC40ºC40ºC40ºC40ºC40ºC40ºC40ºC40ºC40ºC40ºC40ºC40ºC40ºC
Thermic classF (155ºC)F (155ºC)F (155ºC)F (155ºC)F (155ºC)F (155ºC)F (155ºC)F (155ºC)F (155ºC)F (155ºC)F (155ºC)F (155ºC)F (155ºC)F (155ºC)F (155ºC)F (155ºC)F (155ºC)F (155ºC)F (155ºC)F (155ºC)H (180ºC)H (180ºC)H (180ºC)H (180ºC)H (180ºC)
Electric shock protectionClasse IClasse IClasse IClasse IClasse IClasse IClasse IClasse IClasse IClasse IClasse IClasse IClasse IClasse IClasse IClasse IClasse IClasse IClasse IClasse IClasse IClasse IClasse IClasse IClasse I
Test voltage3 kV3 kV3 kV3 kV3 kV3 kV3 kV3 kV3 kV3 kV3 kV3 kV3 kV3 kV3 kV3 kV3 kV3 kV3 kV3 kV3 kV3 kV3 kV3 kV3 kV
A300300300370370370475475545545545615615775775775775775930930930930107010701070
B185185185225225225345345385385385425425575575575575575710710710710880880880
C3053053053753753755205206156156156906909409409409409401275127512751275146014601460
D265265265325325325320320350350350400400400400400400400480480480480660660660
E165165165205205205320320360360360400400550550550550550670670670670840840840
ø77777710101010101010101010101016161616161616
Weight (Kg)16182532364759708695112127156213246293277341470637732823104912441443
TypeXTC101EXTC101EXTC101EXTC102EXTC102EXTC102EXTC103EXTC103EXTC104EXTC104EXTC104EXTC105EXTC105EXTC106EXTC106EXTC106EXTC106EXTC106EXTC107EXTC107EXTC107EXTC107EXTC108EXTC108EXTC108E
GroupYN0YN0YN0YN0YN0YN0YN0YN0YN0YN0YN0YN0YN0YN0YN0YN0YN0YN0YN0YN0YN0YN0YN0YN0YN0