Filtro pasivo de armónicos para VFD IP20

Filtro pasivo de armónicos para convertidores de potencia de 6 pulsos, como variadores de frecuencia para motores, SAIs, rectificadores trifásicos, etc. Construcción bajo envolvente, grado de protección IP-20.

Specifications

Specifications

Potencia del motor
4 ÷ 220 kW
(5,5 ÷ 300 CV)
Corriente nominal 9 ÷ 408 A
Tensión nominal
3 x 400 V ± 20 V
Frecuencia 50 Hz
Armónicos filtrados 3º, 5º, 7º, 11º, 13º
Distorsión 75-100% carga ≈ 5 % THD-I
Distorsión 50-75% carga ≈ 6 % THD-I
Distorsión < 50% carga ≈ 8 % THD-I
Factor potencia 100% carga
≥ 0,99
                        * carga > 40%
≥ 0,9
Temp. Ambiente 30 ºC
Índice de protección IP-20
Refrigeración Natural
Marcado CE
Norma IEC/UNE-EN 60076-6
IEC/UNE-EN 61006-6

Downloads

Contact us for further information

Contact us for further information

Electrical diagram

 

Dimensions

 
Referencias 1 a 1 de 1
  SPF004 SPF005 SPF007 SPF011 SPF015 SPF018 SPF022 SPF030 SPF037 SPF045 SPF055 SPF075 SPF090 SPF110 SPF132 SPF150 SPF160 SPF185 SPF200 SPF220
Request offer Request Request Request Request Request Request Request Request Request Request Request Request Request Request Request Request Request Request Request Request
Power (kW) 4 5,5 7,5 11 15 18,5 22 30 37 45 55 75 90 110 132 150 160 185 200 220
Power (CV) 5,5 7,5 10 15 20 25 30 40 50 60 75 100 125 150 180 205 220 270 270 300
Current (A) 9 12 16 23 30 37 43 58 72 86 104 140 168 204 245 278 296 341 369 406
Losses (W) 165 190 225 310 350 405 450 565 610 670 720 975 1145 1345 1435 1505 1610 1660 1835 1835
IP 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20
Phases Three-phase Three-phase Three-phase Three-phase Three-phase Three-phase Three-phase Three-phase Three-phase Three-phase Three-phase Three-phase Three-phase Three-phase Three-phase Three-phase Three-phase Three-phase Three-phase Three-phase
Use Line for VFD Line for VFD Line for VFD Line for VFD Line for VFD Line for VFD Line for VFD Line for VFD Line for VFD Line for VFD Line for VFD Line for VFD Line for VFD Line for VFD Line for VFD Line for VFD Line for VFD Line for VFD Line for VFD Line for VFD
Ambient temperature 30ºC 30ºC 30ºC 30ºC 30ºC 30ºC 30ºC 30ºC 30ºC 30ºC 30ºC 30ºC 30ºC 30ºC 30ºC 30ºC 30ºC 30ºC 30ºC 30ºC
Electric shock protection Classe I Classe I Classe I Classe I Classe I Classe I Classe I Classe I Classe I Classe I Classe I Classe I Classe I Classe I Classe I Classe I Classe I Classe I Classe I Classe I
Converter voltage 380V ÷ 420V 380V ÷ 420V 380V ÷ 420V 380V ÷ 420V 380V ÷ 420V 380V ÷ 420V 380V ÷ 420V 380V ÷ 420V 380V ÷ 420V 380V ÷ 420V 380V ÷ 420V 380V ÷ 420V 380V ÷ 420V 380V ÷ 420V 380V ÷ 420V 380V ÷ 420V 380V ÷ 420V 380V ÷ 420V 380V ÷ 420V 380V ÷ 420V
A 290 290 290 330 330 330 330 410 410 410 410 490 490 570 570 570 570 570 570 570
B 250 250 250 315 315 315 315 390 390 390 390 410 410 470 470 470 470 470 470 470
C 510 510 510 610 610 610 610 670 670 670 670 1275 1275 1520 1520 1520 1520 1520 1520 1520
Weight (Kg) 21,0 24,6 27,2 34,3 40,7 50,4 56,0 66,2 84,5 94,4 105 129 147 193 222 235 269 298 320 356
Type 1 1 1 1 1 1 1 1 1 1 1 2 2 2 2 2 2 2 2 2