Sinusoidal output filters for VFD IP00

Three phase sine wave voltage output filters especially designed for frequency converters. Remove pulses generated by the output voltage of the frequency converters PWM (pulse width modulation) at high frequencies and restore sinusoidal waveform at power converter´s output.

Specifications

Specifications

Potencia del motor
0,37 ÷ 220 kW
(0,5 ÷ 300 CV)
Corriente nominal 1 ÷ 500 A
Tensión de salida del convertidor
400 V ± 20 V
Frecuencia de salida del convertidor
0 ÷ 70 Hz
Frecuencia de conmutación 2 ÷ 8 kHz
Distorsión de la tensión
≈ 8 % THD-U
Sobrecarga admisible Permanente 1,07× I nom.
Transitoria 1,5× I nom.
Temp. Ambiente 50 ºC
Clase térmica H (180ºC)
Índice de protección IP-00 (hasta LC040)
IP-20 (desde LC050)
Refrigeración Natural
Marcado CE
Norma IEC/UNE-EN 60076-6
IEC/UNE-EN 61588-2-20

Downloads

Contact us for further information

Contact us for further information

Please read the Terms of Service and Privacy Policy and confirm you agree with them before sending the form.

Electrical diagram

 

Dimensions

 
Referencias 1 a 1 de 1
  LC001 LC002 LC004 LC006 LC008 LC010 LC015 LC020 LC025 LC030 LC040 LC050 LC060 LC080 LC100 LC125 LC150 LC200 LC250 LC300 LC400 LC500
Request offer Request Request Request Request Request Request Request Request Request Request Request Request Request Request Request Request Request Request Request Request Request Request
Power (kW) 0,37 0,75 1,5 2,2 3 4 5,5 7,5 11 15 18,5 22 30 37 45 55 75 90 110 150 185 220
Power (CV) 0,5 1 2 3 4 5,5 7,5 10 15 20 25 30 40 50 60 75 100 125 150 200 250 300
Current (A) 1 2 4 6 8 10 15 20 25 30 40 50 60 80 100 125 150 200 250 300 400 500
Losses (W) 38 48 55 60 73 85 105 123 140 152 161 270 310 400 430 500 565 730 960 1050 1220 1480
IP 20 20 20 20 20 20 20 20 20 20 20 00 00 00 00 00 00 00 00 00 00 00
Phases Three-phase Three-phase Three-phase Three-phase Three-phase Three-phase Three-phase Three-phase Three-phase Three-phase Three-phase Three-phase Three-phase Three-phase Three-phase Three-phase Three-phase Three-phase Three-phase Three-phase Three-phase Three-phase
Use Output for VFD Output for VFD Output for VFD Output for VFD Output for VFD Output for VFD Output for VFD Output for VFD Output for VFD Output for VFD Output for VFD Output for VFD Output for VFD Output for VFD Output for VFD Output for VFD Output for VFD Output for VFD Output for VFD Output for VFD Output for VFD Output for VFD
Ambient temperature 50ºC 50ºC 50ºC 50ºC 50ºC 50ºC 50ºC 50ºC 50ºC 50ºC 50ºC 50ºC 50ºC 50ºC 50ºC 50ºC 50ºC 50ºC 50ºC 50ºC 50ºC 50ºC
Thermic class H (180ºC) H (180ºC) H (180ºC) H (180ºC) H (180ºC) H (180ºC) H (180ºC) H (180ºC) H (180ºC) H (180ºC) H (180ºC) H (180ºC) H (180ºC) H (180ºC) H (180ºC) H (180ºC) H (180ºC) H (180ºC) H (180ºC) H (180ºC) H (180ºC) H (180ºC)
Electric shock protection Classe I Classe I Classe I Classe I Classe I Classe I Classe I Classe I Classe I Classe I Classe I Classe I Classe I Classe I Classe I Classe I Classe I Classe I Classe I Classe I Classe I Classe I
Test voltage 4 kV 4 kV 4 kV 4 kV 4 kV 4 kV 4 kV 4 kV 4 kV 4 kV 4 kV 4 kV 4 kV 4 kV 4 kV 4 kV 4 kV 4 kV 4 kV 4 kV 4 kV 4 kV
Converter voltage 380V ÷ 420V 380V ÷ 420V 380V ÷ 420V 380V ÷ 420V 380V ÷ 420V 380V ÷ 420V 380V ÷ 420V 380V ÷ 420V 380V ÷ 420V 380V ÷ 420V 380V ÷ 420V 380V ÷ 420V 380V ÷ 420V 380V ÷ 420V 380V ÷ 420V 380V ÷ 420V 380V ÷ 420V 380V ÷ 420V 380V ÷ 420V 380V ÷ 420V 380V ÷ 420V 380V ÷ 420V
A 150 150 150 150 150 180 180 240 240 240 240 300 300 300 300 300 300 360 420 420 420 480
B 120 120 135 135 135 150 155 170 170 195 195 192 212 212 222 272 287 318 340 355 380 370
C 190 190 190 195 195 215 220 285 285 285 285 355 355 405 405 379 379 473 550 550 550 620
D 100 100 100 100 100 140 140 200 200 200 200 200 200 200 200 200 200 240 280 280 280 320
E 46 46 61 61 61 82 87 99 99 124 124 105 125 125 135 160 175 174 179 194 219 208
ø 7 7 7 7 7 7 7 7 7 7 7 11 11 11 11 11 11 11 11 11 11 11
Weight (Kg) 2,9 3,3 4,2 4,7 5 8,5 9,5 15 16 21 22 29 36 43 45 68 77 90 120 135 160 195