Three phase filtering reactor for capacitor banks

Three phase reactor for harmonic rejection filter to compensate the reactive power. Protects capacitors in installations with presence of harmonics. Protection degree IP-00 with varnish finish.

Specifications

Specifications

 
Line voltage
400V
Network overvoltage
106% x U1
Harmonic distortion THD-U 3º = 0,5%
5º = 6%
7º = 5%
11º = 3,5%
13º = 3%
Frequency
50 Hz
Resonance frequency
189 Hz (p = 7%)
Capacitor voltage
440V
Inductance tolerance
3%
Admissible overload 1,1 x I.nom
Linearity 1,6 x I.nom
Ambient temp.
40 ºC
Insulation class
F (155ºC)
Protection degree
IP-00
Cooling Natural Air
Safety class Class I
Test voltage
4 kV
Protection Bimetal thermal contact
Marked CE
Standard IEC/UNE-EN 60076-6

 

 

Downloads

Contact us for further information

Contact us for further information

Please read the Terms of Service and Privacy Policy and confirm you agree with them before sending the form.

Electrical diagram

Dimensions

 
Referencias 1 a 1 de 1
  IRT002 IRT005 IRT006 IRT010 IRT012 IRT015 IRT020 IRT025 IRT030 IRT040 IRT050 IRT060 IRT075 IRT100
Request offer Request Request Request Request Request Request Request Request Request Request Request Request Request Request
Power (kVAr) 2,5 5 6,25 10 12,5 15 20 25 30 40 50 60 75 100
Current (A) 4,1 8,2 10,2 16,4 20,5 24,5 32,7 40,9 49,1 65,4 81,8 98,2 122,7 163,6
L (mH) 15,331 7,665 6,132 3,833 3,066 2,555 1,916 1,533 1,278 0,958 0,767 0,639 0,511 0,383
Input Voltage(V) 400V 400V 400V 400V 400V 400V 400V 400V 400V 400V 400V 400V 400V 400V
Output Voltage (V) 440V 440V 440V 440V 440V 440V 440V 440V 440V 440V 440V 440V 440V 440V
IP 00 00 00 00 00 00 00 00 00 00 00 00 00 00
Phases Three-phase Three-phase Three-phase Three-phase Three-phase Three-phase Three-phase Three-phase Three-phase Three-phase Three-phase Three-phase Three-phase Three-phase
Use Capacitors bank Capacitors bank Capacitors bank Capacitors bank Capacitors bank Capacitors bank Capacitors bank Capacitors bank Capacitors bank Capacitors bank Capacitors bank Capacitors bank Capacitors bank Capacitors bank
Frequency 50 Hz 50 Hz 50 Hz 50 Hz 50 Hz 50 Hz 50 Hz 50 Hz 50 Hz 50 Hz 50 Hz 50 Hz 50 Hz 50 Hz
Ambient temperature 40ºC 40ºC 40ºC 40ºC 40ºC 40ºC 40ºC 40ºC 40ºC 40ºC 40ºC 40ºC 40ºC 40ºC
Thermic class F (155ºC) F (155ºC) F (155ºC) F (155ºC) F (155ºC) F (155ºC) F (155ºC) F (155ºC) F (155ºC) F (155ºC) F (155ºC) F (155ºC) F (155ºC) F (155ºC)
Electric shock protection Classe I Classe I Classe I Classe I Classe I Classe I Classe I Classe I Classe I Classe I Classe I Classe I Classe I Classe I
Test voltage 4 kV 4 kV 4 kV 4 kV 4 kV 4 kV 4 kV 4 kV 4 kV 4 kV 4 kV 4 kV 4 kV 4 kV
Tuning p = 7% p = 7% p = 7% p = 7% p = 7% p = 7% p = 7% p = 7% p = 7% p = 7% p = 7% p = 7% p = 7% p = 7%
A 150 180 180 180 240 240 240 240 265 265 265 300 300 300
B 90 100 125 145 135 135 155 155 170 170 155 190 185 195
C 150 190 190 190 215 210 210 210 250 250 245 245 305 305
D 100 140 140 140 200 200 200 200 200 200 200 200 200 200
E 62 61 86 106 88 88 108 108 113 113 123 157 137 146
ø 7 7 7 7 7 7 7 7 7 7 7 7 11 11
Weight (Kg) 3 5 8 10 10 11 16 16 22 23 26 38 43 47
Type I I I I II II II II II II III III III III