Three phase output line reactors for VFD

Three phase filter reactor for converters at output side. It is installed between the output of the converter VDF and motor drive. Protection degree IP-00 with epoxy varnish finished.

Specifications

Specifications

 
Motor rating 0,75 ÷ 220 kW (1 ÷ 300 CV)
Nominal current
2 ÷ 500 A
Nominal voltage
380 V - 500 V
Inductive impedance
± 3%
Max. converter output freq. 0 ÷ 70 Hz
Max. conmutation freq.
10 kHz
Admissible overload Permanent 1,07 x I.nom
Transitory 1,5 x I.nom
Ambient temp.
50 ºC @ I.nom
Insulation class
F (155ºC)
Protection degree
IP-00
Cooling Natural air
Safety class Class I
Test voltage
4 kV
Marked CE
Standard IEC/UNE-EN 60076-6

 

 

Downloads

Contact us for further information

Contact us for further information

Please read the Terms of Service and Privacy Policy and confirm you agree with them before sending the form.

Electrical diagram

 

Dimensions

 
Referencias 1 a 1 de 1
  IMT002 IMT004 IMT006 IMT008 IMT010 IMT015 IMT020 IMT025 IMT030 IMT040 IMT050 IMT060 IMT080 IMT100 IMT125 IMT150 IMT200 IMT250 IMT300 IMT400 IMT500
Request offer Request Request Request Request Request Request Request Request Request Request Request Request Request Request Request Request Request Request Request Request Request
Current (A) 2 4 6 8 10 15 20 25 30 40 50 60 80 100 125 150 200 250 300 400 500
L (mH) 10,982 5,491 3,661 2,745 2,196 1,464 1,098 0,879 0,732 0,549 0,439 0,366 0,275 0,220 0,176 0,146 0,110 0,088 0,074 0,055 0,044
Input Voltage(V) 380V ÷ 500V 380V ÷ 500V 380V ÷ 500V 380V ÷ 500V 380V ÷ 500V 380V ÷ 500V 380V ÷ 500V 380V ÷ 500V 380V ÷ 500V 380V ÷ 500V 380V ÷ 500V 380V ÷ 500V 380V ÷ 500V 380V ÷ 500V 380V ÷ 500V 380V ÷ 500V 380V ÷ 500V 380V ÷ 500V 380V ÷ 500V 380V ÷ 500V 380V ÷ 500V
IP 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
Phases Three-phase Three-phase Three-phase Three-phase Three-phase Three-phase Three-phase Three-phase Three-phase Three-phase Three-phase Three-phase Three-phase Three-phase Three-phase Three-phase Three-phase Three-phase Three-phase Three-phase Three-phase
Use Output for VFD Output for VFD Output for VFD Output for VFD Output for VFD Output for VFD Output for VFD Output for VFD Output for VFD Output for VFD Output for VFD Output for VFD Output for VFD Output for VFD Output for VFD Output for VFD Output for VFD Output for VFD Output for VFD Output for VFD Output for VFD
Frequency 50 Hz 50 Hz 50 Hz 50 Hz 50 Hz 50 Hz 50 Hz 50 Hz 50 Hz 50 Hz 50 Hz 50 Hz 50 Hz 50 Hz 50 Hz 50 Hz 50 Hz 50 Hz 50 Hz 50 Hz 50 Hz
Ambient temperature 50ºC 50ºC 50ºC 50ºC 50ºC 50ºC 50ºC 50ºC 50ºC 50ºC 50ºC 50ºC 50ºC 50ºC 50ºC 50ºC 50ºC 50ºC 50ºC 50ºC 50ºC
Thermic class F (155ºC) F (155ºC) F (155ºC) F (155ºC) F (155ºC) F (155ºC) F (155ºC) F (155ºC) F (155ºC) F (155ºC) F (155ºC) F (155ºC) F (155ºC) F (155ºC) F (155ºC) F (155ºC) F (155ºC) F (155ºC) F (155ºC) F (155ºC) F (155ºC)
Electric shock protection Classe I Classe I Classe I Classe I Classe I Classe I Classe I Classe I Classe I Classe I Classe I Classe I Classe I Classe I Classe I Classe I Classe I Classe I Classe I Classe I Classe I
Test voltage 4 kV 4 kV 4 kV 4 kV 4 kV 4 kV 4 kV 4 kV 4 kV 4 kV 4 kV 4 kV 4 kV 4 kV 4 kV 4 kV 4 kV 4 kV 4 kV 4 kV 4 kV
A 120 120 120 150 150 150 190 190 190 240 240 240 240 300 300 300 300 300 360 360 420
B 75 84 84 73 98 98 108 113 123 131 131 151 166 163 183 173 183 193 210 210 280
C 122 122 122 149 164 164 205 205 205 209 209 209 209 252 252 302 302 302 363 363 470
D 94 94 94 100 100 100 140 140 140 200 200 200 200 200 200 200 200 200 320 320 280
E 47 57 57 47 62 62 72 77 87 90 90 110 125 100 120 110 120 130 130 130 165
ø 6,5 6,5 6,5 7 7 7 7 7 7 7 7 7 7 11 11 11 11 11 11 11 11
Weight (Kg) 1,2 1,7 1,8 2,3 3,7 3,9 5,4 6,2 7,6 9,6 10,1 14,7 18,4 21,1 28 28,8 34,4 39,3 52,4 55,7 87,1
Type I I I I I I II II II II II II II III III III III III III III III